Burkert Type 8624 Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 124
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
10 - 8624-2 Standard
english
5.2 Changing the cable outlet direction
Unscrew the 4 screws on the front
panel of the flow pressure controller and
remove the cover carefully.
Remove the screw to the valve and
remove the plastic cross.
Detach the plate from the cube.
Pull out the cube downwards and
replace in the desired orientation.
Place the plate onto the cube (the pins
must engage in the guides).
Lay on the plastic cross and insert the
screw through the cube.
Connect the flow pressure controller to
the proportional valve (see 5.1).
Fig.: Changing the cable outlet direction
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 123 124

Kommentare zu diesen Handbüchern

Keine Kommentare