- Thread G¾ A, ¾ NPT 75 Nm (55 lbf ft)
- Thread G1 A, 1 NPT 100 Nm (73 lbf ft)
High voltage test (enamel) max. 5 KV
Gas-tight leadthrough (optional)
- Leakage rate < 10
-6
mbar l/s
- Pressure resistance PN 64
Output variable
Output Two-wire NAMUR output
Current consumption
- Falling characteristics 2.6 mA uncovered/ 0.6 mA covered
- rising characteristics 0.6 mA uncovered/ 2.6 mA covered
- Fault message 0.6 mA
Necessary processing system NAMUR processing system according to
IEC 60947-5-6 (EN 50227/DIN 19234)
Modes (NAMUR output adjustable to falling or rising characteristics)
- Min. rising characteristic curve (High current when
immersed)
- Max. falling characteristics (Low current when immersed)
Measuring accuracy
Deviation ± 1 mm (0.04 in)
26 LEVEL SWITCH 8111 with NAMUR output