6 Set up
6.1 General information
The gures in brackets refer to the following illustrations.
The switching condition of the electronics can be checked with closed
housing cover (control lamp). In the basic setting, products with a
density > 0.7 g/cm³ (0.025 lbs/in³) can be detected. For products with
lower density, the sw itch must be set to > 0.5 g/cm³ (0.018 lbs/in³).
On the electronics module you will nd the following indicating and
adjustment elements:
l Signal lamp (1)
l DIL switch for mode adjustment - A/B (2)
l DIL switch for sensitivity adjustment (3)
Note:
For test purposes, immerse the tuning fork of LEVEL SWITCH 8112
always in liquids. Do not test the function of LEVEL SWITCH 8112 with
your hand. This can damage the sensor.
6.2 Adjustment elements
1
2
3
4
5
6
7
8
1
2
3
Fig. 12: Oscillator SWE60R - Relay output
1 Signal lamp (LED)
2 DIL switch for mode adjustment
3 DIL switch for sensitivity adjustment
Control lamp for indication of the switching status
l green = relay energized
l red = relay deenergized
l red (ashing) = failure
Func
tion/Conguration
Sig
nal lamp (1)
20 LEVEL SWITCH 8112 - Relay (DPDT)