1
2
-50 °C
(-58 °F)
0°C
(32 °F)
50°C
(122 °F)
100°C
(212 °F)
150°C
(302 °F)
200°C
(392 °F)
250°C
(482 °F)
20
(290)
-1 (-14,5)
40
(580)
64
(928)
Fig. 27: Process temperature - Process pressure with switch position 0.5 g/cm³ (sensitivity switch)
1 Process pressure in bar (psig)
2 Process temperature in °C (°F)
Viscosity - dynamic 0.1 … 10,000 mPa s (requirement: with density 1)
Flow velocity max. 6 m/s (with a viscosity of 1 mPa s)
Density 0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³); 0.5 … 2.5 g/
cm³ (0.018 … 0.09 lbs/in³) by switching over
Electrical protective measures
Protection rating IP 66/IP 67
Overvoltage category III
Protection class II
Adjustment elements
Mode switch
- Min. rising characteristic curve (High current when
immersed)
- Max. falling characteristics (Low current when immersed)
Sensitivity switch
- 0.5 0.5 … 2.5 g/cm³ (0.018 … 0.9 oz/in³)
- 0.7 0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)
Test key simulation of a line break between sensor and
processing unit
Voltage supply
Operating voltage (characteristics according
to standard)
for connection to an amplifier according to NAMUR
IEC 60947-5-6, approx. 8.2 V
Off-load voltage U
0
approx. 8.2 V
Shortcircuit current I
U
approx. 8.2 mA
LEVEL SWITCH 8112 • with NAMUR output 31