Supply and signal circuit
Terminal no. 1[+], no. 2[-] In ignition protection type intrinsic safety EEx ia
IIC/IIB
Only for connection to a certied intrinsically
safe circuit.
Maximum values:
Ui = 20 V
Ii = 103 mA
Pi = 516 mW
Li = negligibly small
Ci = negligibly small
The intrinsically safe circuits are electrically separated from parts which can be grounded.
For applications requiring instruments of category 2G or 1/2G, the intrinsically safe power
supply and signal circuit can correspond to protection class ia or ib. For connection to a circuit
of category ib, the ignition protection type identication is EEx ib IIC T6.
Tip:
Ignition protection type identication: II 2G EEx ia IIB T6, II 2G EEx ib IIB T6 resp. II 1/
2G EEx ia IIB T6 in case of power supply via a circuit of group IIB.
3.2 Application conditions
3.2.1 Permissible ambient temperatures
On the sensor - category 1/2G
Temperature class
- T6 -20 +85 °C
- T5 -20 +100 °C
- T4 -20 +135 °C
- T3 without temperature adapter -20 +150 °C
- T3 with temperature adapter -20 +200 °C
- T2, T1 with temperature adapter -20 +250 °C
On the sensor - category 2G
Temperature class
- T6 -40 +85 °C
- T5 -40 +100 °C
- T4 -40 +135 °C
- T3 without temperature adapter -40 +150 °C
6 LEVEL SWITCH LS8111.C******N*; LEVEL SWITCH LS8112.C******N*